Project Description

APL
PROBES
Liquid level

Measuring range: 5m
Resolution : <1mm
Repeatability: ±0.5% PE

Temperature (internal or remote)

Range: -25°C to +70°C
Resolution : 0,6°C

APPLICATIONS

Water level monitoring for buildings, monuments, bridges, engineering structures

Each sensor is autonomous; it doesn’t need another box nor a sending station

SENSOR

IoT, LoRa, LoRaWAN™
High capacity Li-ion cell
13,5cm x 13,5cm x 6cm
Operating temperature: -30°C to +85°C
1 to 3 probes per sensor

separateurwebpdf

Description

Autonomous sensor with piezometric sensors that can measure small variations in liquid level.

Each sensor is autonomous; it does not need another box or a sending station

Applications

Monitoring in buildings, tunnels or other elements with water presence.

pagebreak
Sensor characteristics
Data recording
Local measurement interval 1 second (via Bluetooth application)
Data reporting interval 30 minutes (configurable)
Reported data Liquid level (1 à 3)
Case temperature
Battery voltage
Liquid level sensor
Measurement principle Piezometric
Measuring range 0 … 5m
Resolution ±1mm
Repeatability ±2.5cm (5m cable)
Operating temperature -20 … +80°C
Temperature sensor inside the housing
Measuring principle NTC
Measuring range -55 … +125°C
Resolution 0,6°C (-5 … +50°C)

pagebreak
Long distance radio
Radio technology LoRaWAN
Security AES-128 data encryption
Supported features LoRa private or operated, OTAA
Radio range Up to 15 km
Transmitted power Up to 20 dBm (adaptive)
Receiver sensitivity -142 dBm
Frequency band 868 MHz (EU), 915MHz (US, AS, AU)
Antenna Internal or external to the housing
Local radio
Radio technology Bluetooth Low Energy
Radio range Up to 40m
Transmitted power Up to 4 dBm
Receiver sensitivity -96 dBm
Frequency band 2.4 GHz ISM
Antenna Internal to the box

pagebreak
Power supply
Battery type Lithium-Ion
Power consumption < 1mW
Battery life *
Measurement period Duration (up to)
30 minutes 5 years
1 hour 10 years

* Indicative durations, for a use in the conditions of use and according to the number of connected sensors, their characteristics and their validation by our research department

Sensor
Operating temperature -30 … +85°C
Dimension 135 x 135 x 60 mm
Weight 350g
Internal memory 1024 measurements
Case Polycarbonate (weather, UV and impact resistant)
Decompressor against condensation
IP65, IK07
Fixing brackets

pagebreak
Order references
Order references
APL-01 piezometer with 1 probe (5m cable length)
APL-02 piezometer with 2 probes (5m cable length)
APL-03 piezometer with 3 probes (5m cable length)

Other options : contact us

pagebreak
Warnings

Specifications and information in this document are subject to change without notice.

A3IP products are not warranted or licensed for use as a critical component for medical or other life-saving or life-sustaining applications, or other applications where failure could reasonably be expected to cause serious injury, death, or damage to any structure, work or building.

In addition, devices are indications and decision aids and cannot be used in alarm or critical applications.

Contact

https://www.a3ip.com

contact@a3ip.com

+33 (0)2 40 94 78 41

A3IP
Bâtiment Placel
Route de Vannes
44880 SAUTRON
France

INFORMATION REQUEST