PROBES
Displacement
Measuring range: 40m (80m in option)
Resolution: <0.1mm
Repeatability : <±1mm
Temperature (internal or remote)
Range: -25°C to +70°C
Resolution: 0,6°C
APPLICATIONS
Indoor or outdoor
Distance monitoring for buildings, monuments, bridges, engineering structures
Each sensor is autonomous; it doesn’t need another box nor a sending station
SENSOR
IoT, LoRa, LoRaWAN™
High capacity Li-ion cell
13,5cm x 13,5cm x 6cm
Operating temperature: -30°C to +80°C
1 to 6 probes per sensor
separateurwebpdf
Description
Autonomous sensor with laser sensors that can measure small changes in distance.
Combined, they allow for very precise monitoring of monuments or tunnels.
Each sensor is autonomous; it doesn’t need another box nor a sending station
Applications
Monitoring of buildings, bridges, monuments, engineering structures
pagebreak
Sensor characteristics
Data recording
Local measurement interval | 1 second (via Bluetooth application) |
Data reporting interval | 30 minutes (configurable) |
Reported data | Distance (1 to 6) |
Case temperature | |
Battery voltage |
Distance probe
Measurement principleOptics (laser) | |
---|---|
Measuring range | 0 … 40m |
Type | Visible red laser, class II, 655nm |
Resolution | ±0.1mm |
Repeatability | ±1mm |
Operating temperature | -10 … +55°C (-40°C in option) |
Temperature sensor inside the housing
Measuring principle | NTC |
---|---|
Measuring range | -55 … +125°C |
Resolution | 0,6°C (-5 … +50°C) |
pagebreak
Long distance radio
Radio technology | LoRaWAN |
---|---|
Security | AES-128 data encryption |
Supported features | LoRa private or operated, OTAA |
Radio range | Up to 15 km |
Transmitted power | Up to 20 dBm (adaptive) |
Receiver sensitivity | -142 dBm |
Frequency band | 868 MHz (EU), 915MHz (US, AS, AU) |
Antenna | Internal or external to the housing |
Local radio
Radio technology | Bluetooth Low Energy |
---|---|
Radio range | Up to 40m |
Transmitted power | Up to 4 dBm |
Receiver sensitivity | -96 dBm |
Frequency band | 2.4 GHz ISM |
Antenna | Internal to the box |
pagebreak
Power supply
Battery type | Lithium-Ion | ||||||
---|---|---|---|---|---|---|---|
Power consumption | < 1mW | ||||||
Battery life * |
|
* Indicative duration, for use in the conditions of use and depending on the number of connected sensors and their characteristics
Sensor
Operating temperature | -30 … +80°C |
---|---|
Dimension | 135 x 135 x 60 mm |
Weight | 350g |
Internal memory | 1024 measurements |
Case | Polycarbonate (weather, UV and impact resistant) |
Decompressor against condensation | |
IP65, IK07 | |
Fixing brackets |
pagebreak
Order references
Order references
ALL-01 | distance meter with 1 laser (40m, cable length 2m) |
---|---|
ALL-02 | distance meter with 2 lasers (40m, cable length 2m) |
ALL-03 | distance meter with 3 lasers (40m, cable length 2m) |
ALL-04 | distance meter with 4 lasers (40m, cable length 2m) |
ALL-05 | distance meter with 5 lasers (40m, cable length 2m) |
ALL-06 | distance meter with 6 lasers (40m, cable length 2m) |
ALL-01-80 | distance meter with 1 lasers (80m, cable length 2m) |
ALL-02-80 | distance meter with 2 lasers (80m, cable length 2m) |
ALL-03-80 | distance meter with 3 lasers (80m, cable length 2m) |
ALL-04-80 | distance meter with 4 lasers (80m, cable length 2m) |
ALL-05-80 | distance meter with 5 lasers (80m, cable length 2m) |
ALL-06-80 | distance meter with 6 lasers (80m, cable length 2m) |
Other options: contact us
pagebreak
Warnings
Specifications and information in this document are subject to change without notice.
A3IP products are not warranted or licensed for use as a critical component for medical or other life-saving or life-sustaining applications, or other applications where failure could reasonably be expected to cause serious injury, death, or damage to any structure, work or building.
In addition, devices are indications and decision aids and cannot be used in alarm or critical applications.