Project Description
PROBES
Gauge bridge inputs
Wheatstone bridge half bridge, quarter bridge or full bridge
Resolution : < 0,0015% (96dB)
Temperature (internal or remote)
Range: -25°C to +70°C
Resolution : 0,6°C
APPLICATIONS
Use of probes with strain-gauge output, for all types of instrumentation.
Makes already installed probes connected or facilitates installation for new installations.
Each sensor is autonomous; it doesn’t need another box nor a sending station
SENSOR
IoT, LoRa, LoRaWAN™
High capacity Li-ion cell
13,5cm x 13,5cm x 6cm
Operating temperature: -30°C to +85°C
1 to 4 probes per sensor
separateurwebpdf
Description
Use of probes with strain-gauge output, for all types of instrumentation.
Makes already installed probes connected or facilitates installation for new installations.
Each sensor is autonomous; it doesn’t need another box nor a sending station
Applications
All types of instrumentation.
pagebreak
SENSOR CHARACTERISTICS
DATA RECORDING
Local measurement interval | 1 second (via Bluetooth application) |
Data reporting interval | 60 minutes (configurable) |
Reported data | Voltage of connected probes |
Case temperature | |
Battery voltage |
Gauge bridge sensor
Measurement principle | Quarter, half or full bridge |
---|---|
Bridge power supply | 3,3V, 10V or 24V |
Resolution | < 0,0015% |
Temperature sensor inside the housing
Measuring principle | NTC |
---|---|
Measuring range | -55 … +125°C |
Resolution | 0,6°C (-5 … +50°C) |
pagebreak
Long distance radio
Radio technology | LoRaWAN |
---|---|
Security | AES-128 data encryption |
Supported features | LoRa private or operated, OTAA |
Radio range | Up to 15 km |
Transmitted power | Up to 20 dBm (adaptive) |
Receiver sensitivity | -142 dBm |
Frequency band | 868 MHz (EU), 915MHz (US, AS, AU) |
Antenna | Internal or external to the housing |
Local radio
Radio technology | Bluetooth Low Energy |
---|---|
Radio range | Up to40m |
Transmitted power | Up to 4 dBm |
Receiver sensitivity | -96 dBm |
Frequency band | 2.4 GHz ISM |
Antenna | Internal to the box |
pagebreak
Power Supply
Battery type | Lithium-Ion | ||||
---|---|---|---|---|---|
Consommation | < 1mW | ||||
Power consumption |
|
* Indicative duration, for use in the conditions of use and according to number of connected sensors, their characteristics and their validation by our engineering department
Sensor
Operating temperature | -30 … +85°C |
---|---|
Dimension | 135 x 135 x 60 mm |
Weight | 350g |
Internal memory | 1024 measurements |
Case | Polycarbonate (weather, UV and impact resistant) |
Decompressor against condensation | |
IP65, IK07 | |
Fixing brackets |
pagebreak
Order references
Order references
AJL-01-1 | Full bridge sensor with 1 entry |
---|---|
AJL-01-2 | Half bridge sensor with 1 entry |
AJL-01-4 | Quarter bridge sensor with 1 entry |
AJL-02-1 | Full bridge sensor with 2 entries |
AJL-02-2 | Half bridge sensor with 2 entries |
AJL-02-4 | Quarter bridge sensor with 2 entries |
AJL-03-1 | Full bridge sensor with 3 entries |
AJL-03-2 | Half bridge sensor with 3 entries |
AJL-03-4 | Quarter bridge sensor with 3 entries |
AJL-04-1 | Full bridge sensor with 4 entries |
AJL-04-2 | Half bridge sensor with 4 entries |
AJL-04-4 | Quarter bridge sensor with 4 entries |
Other options : contact us
pagebreak
Warnings
Specifications and information in this document are subject to change without notice.
A3IP products are not warranted or licensed for use as a critical component for medical or other life-saving or life-sustaining applications, or other applications where failure could reasonably be expected to cause serious injury, death, or damage to any structure, work or building.
In addition, devices are indications and decision aids and cannot be used in alarm or critical applications.
Contact
https://www.a3ip.com
contact@a3ip.com
+33 (0)2 40 94 78 41
A3IP
Bâtiment Placel
Route de Vannes
44880 SAUTRON
France