Project Description
PROBES
Displacement
Measuring range: 25mm (up to 200mm)
Resolution: <±2μm (25mm)
Temperature (internal or remote)
Range: -25°C to +70°C
Resolution : 0,6°C
APPLICATIONS
Indoor or outdoor
Cracks monitoring (1 to 3 axes) for buildings, monuments, bridges, dams, engineering structures…
Monitoring of joints on structures
Each sensor is autonomous; it doesn’t need another box nor a sending station
SENSOR
IoT, LoRa, LoRaWAN™
High capacity Li-ion cell
10,5cm x 10,5cm x 6cm
Operating temperature: -30°C to +85°C
1 to 4 probes per sensor
separateurwebpdf
Description
Autonomous sensor with probes; they are linear potentiometers measuring extremely small displacements.
They measure the cracks evolution or the contraction or joints extension.
Combined, several sensors can be used to monitor cracks in 3D.
Mechanical fixing and selfaligning linkage using 2 ball-joints.
Each sensor is autonomous; it does not need another box or a sending station
Applications
Monitoring in buildings, bridges, pipelines, dams.
pagebreak
Sensor characteristics
Data recording
Local measurement interval | 1 second (via Bluetooth application) |
Data reporting interval | 10 minutes (configurable) |
Reported data | Probe distance (1 to 4) |
Case temperature | |
Battery voltage |
Motion probe
Measurement principle | Potentiometric |
---|---|
Measuring range | 0 … 25mm (50, 75, 100, 125, 150, 175, 200 mm optional) |
Resolution | < 2 µm |
Repeatability | < 5 µm |
Linearity | ±0,1% |
Operating temperature | -60 … +150°C |
Temperature sensor inside the housing
Measuring principle | NTC |
---|---|
Measuring range | -55 … +125°C |
Resolution | 0,6°C (-5 … +50°C) |
pagebreak
Long distance radio
Radio technology | LoRaWAN |
---|---|
Security | AES-128 data encryption |
Supported features | LoRa private or operated, OTAA |
Radio range | Up to 15 km |
Transmitted power | Up to 20 dBm (adaptive) |
Receiver sensitivity | -142 dBm |
Frequency band | 868 MHz (EU), 915MHz (US, AS, AU) |
Antenna | Internal or external to the housing |
Local radio
Radio technology | Bluetooth Low Energy |
---|---|
Radio range | Up to40m |
Transmitted power | Up to 4 dBm |
Receiver sensitivity | -96 dBm |
Frequency band | 2.4 GHz ISM |
Antenna | Internal to the box |
pagebreak
Power Supply
Battery type | Lithium-Ion | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Power consumption | < 1mW | ||||||||||
Battery life * |
|
* Indicative duration, for use in the conditions of use
Sensor
Operating temperature | -30 … +85°C |
---|---|
Dimension | 105 x 105 x 60 mm |
Weight | 280g |
Internal memory | 1024 measurements |
Case | Polycarbonate (weather, UV and impact resistant) |
Decompressor against condensation | |
IP65, IK07 | |
Fixing brackets |
pagebreak
Order references
Order references
ADLr-01-25 | Fissurometer with 1 probe (stroke 25mm, cable length 1m) fixed with ball-joints |
---|---|
ADLr-01-xx | Fissurometer with 1 probe (specific stroke and cable length*) fixed with ball-joints |
ADLr-02-25 | Fissurometer with 2 probes (25mm stroke, 1m cable length) fixed with ball-joints |
ADLr-02-xx | Fissurometer with 2 probes (specific stroke and cable length*) fixed with ball-joints |
ADLr-03-25 | Fissurometer with 3 sensors (25mm stroke, 1m cable length) fixed with ball-joints |
ADLr-03-xx | Fissurometer with 3 probes (specific stroke and cable length*) fixed with ball-joints |
ADLr-04-25 | Fissurometer with 4 sensors (25mm stroke, 1m cable length) fixed with ball-joints |
ADLr-04-xx | Fissurometer with 4 probes (specific stroke and cable length*) fixed with ball-joints |
* stroke up to 200mm, cable length 1m as standard
Other options : contact us
pagebreak
Warnings
Specifications and information in this document are subject to change without notice.
A3IP products are not warranted or licensed for use as a critical component for medical or other life-saving or life-sustaining applications, or other applications where failure could reasonably be expected to cause serious injury, death, or damage to any structure, work or building.
In addition, devices are indications and decision aids and cannot be used in alarm or critical applications.
Contact
https://www.a3ip.com
contact@a3ip.com
+33 (0)2 40 94 78 41
A3IP
Bâtiment Placel
Route de Vannes
44880 SAUTRON